Service
Grease to bare metal,
fire load down.
Hoods, baffle filters, ducts and roof fans, taken to bare metal.
Specification
Scope, stated plainly.
End-to-end cleaning of hoods, baffle filters, horizontal and vertical ducts, access panels and roof exhaust fans in hotel kitchens, QSRs, cloud kitchens, cafeterias and banquet halls. Grease removal to bare metal where access allows, reducing fire load and cleaning your system to the NFPA 96 standard, the globally recognised kitchen-exhaust fire-safety benchmark.
To NFPA 96 standard
| Item | Scope |
|---|---|
| Hood & filter degreasing | Included |
| Duct interior to bare metal | Included |
| Exhaust fan & plenum service | Included |
| Access panel installation | Included |
| Certificate of Performance | Included |
| Vertical ducts and blower assembly (fan unit) | Add-on, quoted |
| UV light / UV scrubber / air-washer unit cleaning | Add-on, quoted |
| Deep cleans requiring full kitchen shutdown | Add-on, quoted |
| Work outside of agreed operating hours | Add-on, quoted |
| Coil-only cleaning as a standalone scope | Add-on, quoted |
| Fogging / antimicrobial treatment (on request) | Add-on, quoted |
Equipment
The right tool for each duct.
- K-01
Rotary brush system
- K-02
Air Whip
- K-03
Negative Pressure Machine
- K-04
Eco-friendly, metal-safe degreasers
Kitchen-exhaust work follows NFPA 96 guidance
What you receive
Evidence you can file, not just an invoice.
Before and after photographs of every cleaned section
Written chemical-safety guarantee
Certificate of Performance
Sectors servedHotel kitchens · QSRs · Cloud kitchens · Cafeterias · Banquet halls
Before and after
The same duct, before and after.
Open the photo report
Kitchen exhaust duct
Horizontal kitchen duct, grease removed to bare metal.

Hood and baffle filters
Commercial kitchen hood and filters, degreased.

Roof exhaust fan
Kitchen roof exhaust fan impeller and housing.
Representative imagery. Project photos on request.
How it runs
Seven documented steps, every site.
- 01Site survey & scope of work
- 02Method statement, containment & safety
- 03Pre-clean RoboCam inspection
- 04Mechanical cleaning: NPM, rotary brush & Air Whip
- 05AHU, coils, grilles & kitchen hood cleaning
- 06Access ports & microbial sanitisation
- 07Post-clean RoboCam, photo report & Job Completion Certificate
Size it
Estimate your clean from the fan airflow.
It is on the fan nameplate or the air balancing report.
Don't know your CFM? Send us a photo of the fan nameplate.
CFM ÷ 7 = duct area in square feet. We use this as our starting point, then verify on site.
Enter your airflow to see the duct area and a starting estimate.
Typical unit rate for commercial kitchen exhaust cleaning starts at ₹9/sqft. Final rate depends on access, grease load and operating hours.
Plus GST. The vertical riser and fan unit, and UV or air-washer units, are add-ons quoted separately.
Inspection frequency
How often NFPA 96 says to inspect.
Type of cooking
Minimum inspection interval
Every 6 months
NFPA 96 term: Semiannually
These are minimum inspection intervals for the exhaust system. Your authority having jurisdiction, insurer or the grease found on inspection can require cleaning sooner.
Source: NFPA 96 (2024), Table 12.4
Questions
About this service.
Book a free duct inspection.
Tell us the building and the ducts. We reply with a written scope and a quote.
Mon – Sat · 09:30 – 19:00 · Emergency & night-shift cleans on request