What is cleaned
- Supply, return and fresh-air ducts
- AHU and FCU coil cleaning
- Diffuser, grille and VCD cleaning
- Microbial remediation and sanitisation
- Photo and video evidence of every section
See it on the system
Included
Included
- Photo and video evidence of every section
How it is cleaned
Source-removal cleaning of supply, return and fresh-air ducts in office towers, hospitals, hotels, airports, pharma plants and data centres. Negative Pressure Machines, rotary brushes, Air Whip and contact vacuuming, matched to each duct type and contamination profile. Pre- and post-clean RoboCam video. Methods aligned with NADCA's published standards.
Equipment
- Negative Pressure Machine
- Rotary brush system
- Air Whip
- Contact vacuuming
- RoboCam Inspection Video System
Seven steps, every site
01
Site survey & scope of work
We walk the facility, inventory duct runs, identify access points and agree a written scope of work. CFM divided by 7 gives us duct square footage. No assumptions, no surprises on the invoice.
02
Method statement, containment & safety
Before we start, you receive a written method statement and risk assessment covering electrical isolation, working-at-height and confined-space protocols. Plastic containment and negative pressure isolate each zone so contamination cannot escape into occupied space.
03
Pre-clean RoboCam inspection
Our RoboCam crawler records the duct interior on photos and SD-card video, establishing a clear before-state you can see.
04
Mechanical cleaning: NPM, rotary brush & Air Whip
A Negative Pressure Machine on one end, a rotating brush or high-pressure Air Whip on the other. The brush loosens; the NPM captures. Eco-friendly, non-corrosive, metal-safe degreasers are used where grease is present, and we guarantee they will not weaken your ducting.
05
AHU, coils, grilles & kitchen hood cleaning
Blowers, coils, drain pans, dampers, diffusers and grilles are washed or contact-vacuumed. For commercial kitchens, hoods and filters are degreased to bare metal where access allows.
06
Access ports & microbial sanitisation
We cut and make clean access ports wherever the duct lacks them (you provide 24-gauge GI sheet for re-fixing). Where required, a food-safe antimicrobial fog is drawn through the system to eliminate residual mould and bacteria.
07
Post-clean RoboCam, photo report & Job Completion Certificate
A second RoboCam pass documents the after-state. You receive the before/after photo and video report, a cleanliness verification and a signed Job Completion Certificate for your records and your auditors.
Scope your system
Airflow is estimated at 400 CFM per ton (TR), the common rule of thumb for comfort cooling. The survey measures the real figure.
Total tonnage of the system; it is on the AC nameplates or the design drawings.
Airflow is estimated at 400 CFM per ton (TR), the common rule of thumb for comfort cooling. The survey measures the real figure.
Enter the tonnage to see the airflow and what the clean covers.
The inspection measures the duct runs and access points, then you receive a written scope and quote. Plus GST.